Q.01

How do foreign manufacturers register medical devices in Mexico?

A foreign manufacturer cannot hold a Mexican device registration (registro sanitario) on its own. The holder must be a company with an establishment in Mexico that has filed an operating notice (aviso de funcionamiento) as a factory, warehouse/distributor or conditioning site. In practice the manufacturer works through a Mexican subsidiary or an appointed Mexican holder, which files with COFEPRIS by one of three routes: standard, low-risk, or equivalence with a recognised foreign regulator.

1. Legal basis

  • Registration is required. Medical devices "deberán contar con autorización sanitaria" (must have health authorisation) to be sold or supplied [1]. The General Health Law lists the device categories and says the Secretaría classifies them by risk under the Reglamento de Insumos para la Salud (RIS) [2].

  • RIS Art. 82: devices "requieren para su producción, venta y distribución de registro sanitario" (require registration for production, sale and distribution).

  • RIS Art. 83 risk classes:

    • Class I: known devices, generally not introduced into the body.
    • Class II: generally introduced into the body for less than 30 days.
    • Class III: new devices, or devices that stay in the body for more than 30 days.

    (RIS, gob.mx, p. 26)

  • Who can hold the registration (RIS Art. 181): the holder needs an aviso de funcionamiento for a factory, warehouse/distribution or conditioning establishment "establecido en el territorio nacional" (established in Mexico).

  • Extra documents for foreign-made devices (RIS Art. 180):

    • a certificate of free sale (or equivalent) from the country of origin;
    • a manufacturer's letter of representation, if the manufacturer is not the applicant's parent company;
    • a GMP certificate from the authority of the country of origin;
    • the manufacturer's original certificate of analysis.
  • Other distributors (RIS Art. 182): they may use the registration with the manufacturer's and COFEPRIS's authorisation. (RIS, p. 69)

2. The three COFEPRIS routes

Standard (COFEPRIS-04-060)Low risk (COFEPRIS-04-070)Reference-authority equivalence (COFEPRIS-04-050)
ScopeAny device, domestic or foreign-madeDevices on the official low-risk list (Acuerdo, DOF 07/07/2025)Devices already approved by a regulator COFEPRIS recognises
Fee (MXN)16,499 (Class I), 24,198 (Class II), 30,798 (Class III)16,499 fixed16,498.70 (Class I), 24,198.08 (Class II), 30,797.57 (Class III)
Response time20 / 25 / 35 working days for Class I / II / III; Class I gets automatic approval if COFEPRIS does not respond in time (afirmativa ficta)15 working days30 working days
Validity5 years5 years5 years

Sources: [3][4][5]

Standard route, foreign manufacture [3]:

  • form FF-COFEPRIS-21 and proof of fee payment;
  • technical and scientific evidence of safety, efficacy and quality, following the COFEPRIS registration guide for Class I, II and III devices and Appendix III of the FEUM device supplement;
  • certificate of free sale from the country of origin;
  • letter of representation, if the manufacturer is not the applicant's affiliate or parent;
  • draft label in Spanish under the applicable NOM (the sheet cites NOM-137-SSA1-2008);
  • instructions for use in Spanish;
  • GMP certificate from the authority of the country of origin (if it was issued electronically, give the access path);
  • notarial power of attorney or RUPA registration.

Low-risk route: a shorter package: technical information, instructions for use, Spanish label, FF-COFEPRIS-21, fee, and a letter of representation where needed [4].

Equivalence route [5]:

  • Recognised approvals:
    • FDA Class I, II and III (US/Canada agreement, DOF 26/10/2010);
    • Health Canada Class II to IV;
    • Japanese MHLW certificates and approval letters (agreement DOF 25/01/2012);
    • other reference authorities named by agreement.
  • The dossier has 18 items, including:
    • the approval from the reference authority;
    • certificate of free sale;
    • clinical evaluation report;
    • technovigilance report from the country of origin;
    • manufacturing process summary;
    • the conformity assessment that was submitted to the reference authority;
    • certificate of analysis;
    • GMP certificate or equivalent;
    • risk analysis.
  • FDA-specific items:
    • Certificate to Foreign Government;
    • the latest inspection report;
    • the FDA clearance or approval document (510(k), PMA or equivalent);
    • for Class II and III, the latest post-market surveillance report.
  • Health Canada-specific items:
    • notarised device licence;
    • CAN/CSA-ISO 13485:03 certificate;
    • accreditation documents for the third party that issued that certificate.

3. Foreign documents and language

  • Current RIS text (Art. 153, amended DOF 31 May 2021):
    • supporting documents may be in Spanish or English;
    • documents issued by foreign authorities must be apostilled or legalised;
    • documents in any other language need translation by a certified translator (perito traductor).
  • Letters of representation (RIS Art. 161(III)): they must be authenticated by the legal procedure of the country of origin. (RIS, pp. 47-49)
  • Conflict: the 04-050 and 04-070 sheets still say documents must be in Spanish or come with a Spanish translation, signed off by the company's responsible health officer. The RIS text in force says Spanish or English.
  • Labels and instructions: these must be in Spanish whatever route you use (RIS Art. 179).

4. Points that affect planning

  • Two sets of deadlines: RIS Art. 179 still sets 30 / 35 / 60 days for Class I / II / III. The 04-060 sheet gives 20 / 25 / 35 working days and cites the COFEPRIS simplification agreement published 22/08/2025 as its basis. I couldn't open that agreement in the DOF.
  • New models: a new model with technological advances needs a new registration (RIS Art. 84).
  • Changes: changes to registered conditions need COFEPRIS approval first (RIS Art. 184).
  • Post-market: once registered, technovigilance is required (General Health Law Art. 262 Bis, added DOF 15-01-2026) [6].
  • Import permits: importing devices needs health authorisation where the Secretary has said so by agreement published in the DOF [7].
  • The register itself: COFEPRIS's medical-device register lists Mexican companies as holders, for example Solventum México, S. de R.L. de C.V. [8] and Kabla Comercial, S.A. de C.V. [9].

Approach: I used the COFEPRIS procedure sheets for new device registrations, Titles XII-XIII of the General Health Law, the COFEPRIS device register, and the RIS as published on gob.mx. The text of the 22/08/2025 simplification agreement and the 07/07/2025 low-risk lists could not be read.

Sources: Reglamento de Insumos para la Salud (gob.mx)

Q.02

Who can hold the Mexican registration?

Under Mexican law, only a company running a health-products establishment in Mexico can hold the registration. That establishment must have filed an aviso de funcionamiento (operating notice) as a factory or production laboratory, a warehouse or distribution site, or a conditioning site. A foreign manufacturer cannot hold it directly. It needs a Mexican affiliate or subsidiary, or a Mexican company it appoints by letter of representation, to apply and hold the registration.

The rule (RIS Art. 181). "Para ser titular del registro sanitario de los Insumos a que se refiere el Capítulo IX, del Título Segundo de este Reglamento, se requiere contar con aviso de funcionamiento de fábrica o laboratorio de producción, almacén de depósito o distribución o acondicionamiento establecido en el territorio nacional." In English: to be the registration holder for products under Chapter IX of Title Two, you need an operating notice for a factory or production laboratory, a warehouse or distribution site, or a conditioning site established in Mexico. (RIS, gob.mx, p. 69)

What the operating notice involves (General Health Law Art. 200 Bis).

  • It "deberá presentarse por escrito" (must be filed in writing) with the Secretaría de Salud or the state government at least 30 days before operations start.
  • It must give the name and address of the person or company that owns the establishment, the site address, its processes and product lines, its activity code and, where applicable, the professional licence number of the responsable sanitario (the establishment's responsible health officer).

How the COFEPRIS procedure sheets apply this.

  • Who files: an applicant's legal representative (representante legal) or a third party with a power of attorney (tercero con carta poder) can file the standard and low-risk registrations, for domestic or foreign-made devices [3][4]. Whoever files, the holder must still meet Art. 181.
  • Proof of the notice: the equivalence route (COFEPRIS-04-050) asks for a copy of the establishment's operating notice (aviso de funcionamiento, or its latest change) and the notice naming its responsable sanitario [5].
  • Letter of representation:
    • It is needed when the foreign manufacturer is not the applicant's parent, subsidiary or affiliate.
    • The standard-route sheet describes it as the letter "a la que los autoriza como sus distribuidores en México" (authorising them as its distributors in Mexico) [3].
    • The 04-050 sheet says it must be authenticated by the legal procedure of the country of origin [5].

Related rights of other companies (RIS Arts. 182-183).

  • Other distributors "podrá[n]" (may) use an existing registration, with the manufacturer's and the Secretaría's prior authorisation, by presenting the manufacturer's letter of representation and the draft label (Art. 182).
  • Companies other than the holder "sólo podrán" (may only) make the registered products with the holder's authorisation and under the same conditions that were approved (Art. 183).

(RIS, p. 69)

Approach: I used the COFEPRIS procedure sheets for new device registrations and the General Health Law. The Reglamento de Insumos para la Salud is not in the datasets I can search, so I read Articles 180-183 in the official gob.mx text.

Sources: Reglamento de Insumos para la Salud (gob.mx)

Q.03

When can I use the equivalency route?

You can use the equivalence route (COFEPRIS-04-050) when a regulator COFEPRIS recognises has already approved your device for sale. The sheet says it applies "cuando quiera realizar venta y distribución de dispositivos médicos … en territorio nacional, que cuenten con aprobación por una Autoridad regulatoria reconocida por COFEPRIS" (when you want to sell and distribute devices in Mexico that have approval from a regulatory authority COFEPRIS recognises). The approval has to fall into one of six categories, set by class and by regulator [5].

Approvals that qualify

CategoryReference approvalBasis
AFDA Class IUS/Canada equivalence agreement, DOF 26/10/2010
BFDA Class II and IIIUS/Canada agreement, DOF 26/10/2010
CHealth Canada Class II, III and IVUS/Canada agreement, DOF 26/10/2010
DJapan, designated controlled devices (Class II with established conformity criteria), certified by a certification body registered with the MHLWJapan agreement, DOF 25/01/2012
EJapan, Class II without established conformity criteria, and Class III and IV, holding an MHLW approval letterJapan agreement, DOF 25/01/2012
FOther reference regulatory authorities recognised by agreementSeparate agreements

[5]

The sheet names no other regulators. If your device's approval does not fit one of these categories, the route is not open to it. You would use the standard route (COFEPRIS-04-060) instead, or the low-risk route if the device is on the official low-risk list.

Conditions that apply in every case

  • The approval must come from the regulator you rely on. You file the device's marketing authorisation issued by that authority. You also file a certificate of free sale, or its equivalent, issued by the same authority [5].

  • The holder still needs a Mexican establishment. The general requirements include a copy of the establishment's operating notice (aviso de funcionamiento) and of the notice naming its responsable sanitario (responsible health officer). A letter of representation is needed when the device is not made by the applicant's parent, subsidiary or affiliate. That letter must be authenticated by the legal procedure of the country of origin [5].

  • Fees follow Mexican risk classes, not the foreign class. The device must be classified under RIS Art. 83 to work out the fee. The fee is MXN 16,498.70 for Class I, 24,198.08 for Class II and 30,797.57 for Class III [5].

  • Documents tied to specific approvals:

    • FDA (A and B):

      • the Certificate to Foreign Government, as the original or a notarised copy;
      • the latest establishment inspection report;
      • the FDA marketing authorisation (ER&L, 510(k) or PMA);
      • for Class II and III only, a post-market surveillance summary.
    • Health Canada (C):

      • a notarised copy of the device licence;
      • a current CAN/CSA-ISO 13485:03 certificate;
      • the ISO 17021 certificate and a certified copy of the authorisation for the third party that issued the 13485 certificate.
    • Japan (D and E):

      • the certificate from the registered certification body (D) or the MHLW approval letter (E);
      • the export notification;
      • an original certificate of free sale no more than one year old.

      These must be translated by a certified translator (perito traductor) and legalised under RIS Art. 153.

    [5]

What you get

The registration is valid for 5 years. COFEPRIS's response time is 30 working days. It has 10 days to raise an administrative query (prevención) and 20 days for a technical one [5].

The legal basis the sheet gives is the COFEPRIS agreement setting the general guidelines for the abbreviated pathway (vía regulatoria abreviada), which recognises evaluations by reference regulatory authorities and the WHO prequalification programme. It cites Arts. 3(II), 14, 25(B), 26(II) and 31 of that agreement, and RIS Art. 182 [5].

Two points in the sheet are unclear:

  • Category F has no list of authorities. The documents listed under it repeat the Japanese MHLW approval-letter items, so which "other" authorities qualify depends on the agreements themselves. I have not read them.
  • The cited legal basis does not match the sheet's text. The requirements text still relies on the 2010 and 2012 equivalence agreements.

Approach: I read the COFEPRIS-04-050 procedure sheet for registering devices by equivalence with reference regulatory authorities. The text of the abbreviated-pathway guidelines agreement and of the 2010 and 2012 equivalence agreements was not in the datasets I searched, and I have not opened them in the DOF.

Q.04