Q.01

What is a UFI code?

A UFI (Unique Formula Identifier) is an alphanumeric code that the EU CLP Regulation requires for hazardous mixtures notified to poison centres. Annex VIII defines it as "a unique alphanumeric code that unambiguously links the submitted information on the composition of a mixture or a group of mixtures to a specific mixture or group of mixtures" [1]. When a poison centre gets an emergency call, the UFI on the product lets it find the exact formulation that was notified.

Approach: I read the current consolidated text of the EU CLP Regulation (Regulation (EC) No 1272/2008), mainly Articles 25 and 29 and Annex VIII, and the Irish Health and Safety Authority's (HSA) guidance on CLP and safety data sheets.

Who creates it and when

  • The obligation covers mixtures classified as hazardous for health or physical effects. Before placing them on the market, importers and downstream users ("submitters") shall send the composition information to the national bodies appointed under Article 45 (poison centres) [1][2].
  • The submitter shall create the UFI using ECHA's electronic tool (the UFI generator), and it is free of charge [1][3].
  • The UFI shall be included in the poison centre submission [3].
  • A UFI can cover a single mixture or a group submission. A group is allowed where all the mixtures have the same health and physical hazard classification and the same components within the same concentration ranges, or differ only in perfumes totalling no more than 5 % [1].
  • Annex VIII does not apply to mixtures for scientific or product and process oriented R&D, or to mixtures classified only as gases under pressure or explosives [2].

When a new UFI is needed

  • A new UFI shall be created when the composition changes in one of these ways [1][4]:
    • a component is added, substituted or deleted;
    • a concentration moves outside the range given in the original submission;
    • an exact concentration changes by more than the Table 4 limits (for example ±5 % for components above 25 % and up to 100 %).
  • No new UFI is needed when:
    • only the perfumes in a group submission change [1];
    • a substitution stays within an interchangeable component group already in the submission [1].

How it must be shown

  • Format: the code shall be preceded by "UFI:" in capital letters and shall be clearly visible, legible and indelibly marked [3].
  • On the label: it goes in the supplemental information section under Article 25(7) [2]. Article 29(4a) lets the submitter show it another way that Annex VIII permits instead [5]. Those alternatives are:
    • printed or affixed on the inner packaging, together with the other label elements;
    • on the outer packaging, if the inner packaging is too small or the wrong shape;
    • in the safety data sheet (or the copy of the label elements) for unpackaged mixtures;
    • optionally in the safety data sheet for packaged mixtures used at industrial sites [3].
  • Fold-out labels: the UFI goes on the front page, unless it is on the inner packaging [6].
  • Safety data sheet: the Irish HSA says that where a mixture has a UFI, it must be given in SDS subsection 1.1 (product identifier) [7].

Special case: bespoke paints Bespoke paints are paints tinted or colour-mixed at the point of sale. The supplier may choose not to notify them or create a UFI [2]. If no UFI is created, the label shall carry the UFIs of all notifiable mixtures in the paint above 0.1 %, in descending order of concentration. Any of those mixtures present above 5 % shall also have its concentration shown [8].

Timing Annex VIII has applied since 1 January 2021 to mixtures for consumer and professional use, and since 1 January 2024 to mixtures for industrial use. Notifications made under older national schemes were allowed to run until 1 January 2025 [2].

Q.02

When do I need one on my label?

Your label needs a UFI whenever you have created one for the mixture under CLP Annex VIII, which in practice means any hazardous mixture you notify to poison centres. Article 25(7) says that where the submitter creates a UFI, "it shall be included in the supplemental information on the label" [8]. So the label requirement follows directly from the notification duty. Article 29(4a) then lets you show the UFI in another place that Annex VIII permits instead of on the label itself [5].

Approach: I read Articles 25, 29 and 45 and Annex VIII Part A in the current consolidated EU CLP text (Regulation (EC) No 1272/2008, consolidated version of 1 July 2026). This is the EU rule only; GB CLP was not checked.

1. Is the mixture in scope? (if yes, a UFI is needed)

  • Who: the duty sits with importers and downstream users who place mixtures on the market ("submitters") [2].
  • Since when: these dates are long past, so every use type is now covered [2]:
    • consumer and professional mixtures: from 1 January 2021;
    • industrial mixtures: from 1 January 2024;
    • notifications under the old national schemes: could run only until 1 January 2025.
  • Outside Annex VIII, so no UFI is needed [2]:
    • mixtures for scientific R&D, or for product and process oriented R&D;
    • mixtures classified only as gases under pressure and/or explosives (unstable explosives and Divisions 1.1 to 1.6).
  • Bespoke paints (tinted or colour-mixed at the point of sale): you may choose not to notify or create a UFI [2]. If you make that choice, the label shall carry the UFIs of all notifiable mixtures in the paint above 0.1 %, listed together in descending order of concentration. Any of those mixtures above 5 % shall also have its concentration shown [8].

2. Where the UFI goes (Annex VIII, Part A, Section 5.3)

SituationWhere the UFI goes
Standard packaged mixtureSupplemental information section of the label (Art. 25(7)), or, if you choose, printed or affixed on the inner packaging next to the other label elements
Inner packaging too small or the wrong shape for the UFICan go on the outer packaging, next to the other label elements
Packaged mixture supplied for use at an industrial siteOptional: in the safety data sheet instead of on the label or packaging
Unpackaged mixtureShall be in the SDS or in the copy of the label elements under Art. 29(3)

All rows: [3]

Wherever it appears, it shall be preceded by "UFI:" in capitals and be "clearly visible, legible and indelibly marked" [3].

3. When the label has to change

  • If the composition changes in a way that needs a new UFI, the code on the label changes too.
  • You shall update the poison centre submission before placing the changed mixture on the market. A change of product identifier or UFI is one of the listed triggers [9].
  • No new UFI is needed when:
    • only the perfumes in a group submission change, or new perfumes are added;
    • a component is substituted within an interchangeable component group that is already declared in the submission [1].

If you tell me the product's use (consumer, professional or industrial), its packaging and its classification, I can work out exactly where the UFI should go for it.

Q.03

How do I generate and check it?

You generate a UFI in ECHA's free, web-based UFI Generator, from your company's VAT number (or an ECHA "company key") plus a formulation number you assign to the mixture. The same tool has a "validate UFI" function for checking a code [10]. CLP Annex VIII requires the submitter to "create a Unique Formula Identifier ('UFI') by electronic means made available by the Agency", free of charge [1].

Approach: I read CLP Annex VIII Section 5 (EU consolidated text, 1 July 2026) and ECHA's Poison Centres portal guidance, which the datasets hold in its Italian-language version, some of it in English. I also read the German BAuA and Belgian FPS Public Health guidance; ECHA's UFI user guide and developers manual would not open for me.

Generating it

  • What you enter: your company's VAT number (the tool also works without one) and a formulation number specific to the mixture. The tool combines them into your UFI [10].
  • No VAT number, or you'd rather not use it: the UFI Generator can create a "company key" to use instead [10].
  • One code or many: the tool can generate a single UFI or a batch [10].
  • Large portfolios: you can build ECHA's UFI algorithm into your own IT system, following ECHA's UFI Developers Manual. You still need a formulation number plus your VAT number or company key [10].
  • What you get: a 16-character code [11].
  • Allocation rule: all products labelled with the same UFI must contain the same mixture composition [12].
    • Mixture-centric approach: one UFI per mixture, shared by every product that contains it.
    • Product-centric approach: also in common use.
    • Other approaches: ECHA also mentions ones based on market, language or labelling.

Checking it

  1. Is the code itself valid? Use the UFI Generator's "validate UFI" function [10]. I couldn't open ECHA's user guide or developers manual, so I can't tell you what the check tests.

  2. Is it shown correctly? It shall be preceded by "UFI:" in capitals and be "clearly visible, legible and indelibly marked" [3]. For unpackaged mixtures, and as an alternative to the label for products used at industrial sites, ECHA says it goes in SDS section 1.1 [12].

  3. Is it still current? If the composition changes in a way listed in Annex VIII, you need a new UFI [1]. ECHA then says to:

    • generate a new UFI;
    • change the UFI on the product;
    • update your submission to reflect all the changes [13].

    Renaming or repackaging the product, with the composition unchanged, is handled as a submission update [13].

  4. Supplier UFIs for a mixture in your mixture:

    • A UFI can be passed down the supply chain instead of composition data only once poison centres already know it from a submission [14].
    • Make sure your supplier has included it in a submission to the relevant appointed body [14].
    • If it hasn't, you can fall back on the composition in the supplier's SDS plus the EU supplier's name and contact details, but ECHA says to use this only as a last resort [14].

Two related questions appear on the German BAuA helpdesk FAQ, but its answers weren't in the text I could read [15]:

  • whether a merger or demerger means generating new UFIs;
  • whether two unrelated companies could generate the same UFI.

These ECHA documents should cover the code structure and how validation works, but they would not open for me:

The tool itself is on ECHA's UFI Generator page.

Q.04