Silica exposure limits in Great Britain and COSHH controls
Great Britain's respirable crystalline silica limit is 0.1 mg/m³ over eight hours. COSHH also requires exposure prevention or adequate control at work.
Under Great Britain's silica exposure limits, the workplace limit for respirable crystalline silica (RCS) is 0.1 mg/m³ averaged over eight hours. Meeting that limit alone does not satisfy COSHH: employers must prevent exposure where reasonably practicable, or otherwise adequately control it. See HSE's silica guidance and COSHH regulation 7.
This guide covers Great Britain. Do not use it as a statement of Northern Ireland's requirements.
What respirable crystalline silica exposure limits measure
The 0.1 mg/m³ value applies to RCS, not every form of silica or all workplace dust. Cutting or breaking stone, concrete and brick can generate RCS exposure, as HSE explains.
The unit means milligrams per cubic metre of air. The eight-hour time-weighted average describes exposure averaged over that reference period. It is not an instantaneous ceiling, a 15-minute limit or a separate allowance for each short task. Keep the averaging period attached to the number when recording or comparing exposure results. HSE gives both the value and its reference period.
For an official lookup, use HSE's EH40 publication page. EH40 lists Great Britain's workplace exposure limits, and HSE amends the list when new or revised limits are approved. Match the substance and dust fraction to the entry rather than applying a generic dust value. See HSE's explanation of WELs.
Does staying below the limit meet COSHH?
No. A below-limit measurement does not close the assessment. Regulation 7 requires prevention where reasonably practicable. Where prevention is not reasonably practicable, employers must adequately control exposure and apply the good-practice principles, as well as meet the WEL.
EH40 marks RCS as carcinogenic where a work process generates it. For this exposure, regulation 7 requires reduction to as low a level as reasonably practicable. Do not treat 0.1 mg/m³ as the concentration to aim for.
The control order matters. Use appropriate processes and engineering controls, then control dust at source, including ventilation and organisational measures. Suitable personal protective equipment adds protection where those measures cannot achieve adequate control. A respirator does not replace the earlier steps in regulation 7's control hierarchy.
COSHH assessment for silica dust
Start with the work that generates dust. Identify the tasks and people exposed, then choose controls for those conditions. Minimise exposure duration and the number of people exposed, as required by regulation 7.
For construction tasks, HSE describes water suppression and specially designed tools with vacuum extraction that capture dust as it forms. Water must be sufficient throughout the work. Wetting the ground before cutting is not effective. Some high-risk tasks, including using cut-off saws or grinders on silica-containing materials, also need respiratory protective equipment. Follow the task-specific HSE guidance, rather than assuming one mask suits every job.
Check actual exposure. HSE describes air monitoring as measuring the substance in the air a worker breathes during a task. Regulation 10 requires monitoring where the assessment shows it necessary to maintain adequate control or protect health. An exception applies where another evaluation method demonstrates compliance with regulation 7(1). Required monitoring must occur at regular intervals and when changes may affect exposure. There is no single sampling interval to apply to every silica task.
RegAffairs AI's answer on silica exposure limits and COSHH links the underlying regulatory sources.
Health surveillance is a separate decision. HSE requires it for workers regularly exposed to RCS dust where there is a reasonable likelihood that silicosis may develop.